Technical information
12/01/02
47
The sensor has two LED lamps that light to show that
power is supplied. Since the voltage is DC, the sensor is
polarity sensitive. The sensor has four wires. The orange
wire is capped off and not used. The black wire connects
to the coil of relay X7. The brown wire is the positive lead
and connects to terminal J2-1 on the power supply. The
blue wire is the negative lead and connects to terminal J2-
2. If these wires are crossed, the sensor will not shut the
unit down. The result will be that the spout will fill with ice
causing higher gear motor current and the gear motor pro-
tect fuse will blow. In this case, the bin control is the first
component to check.
The sensor has two adjustments that are factory set. The
first adjustment sets the operation mode of the sensor. It
must be in the D position. The second adjust the operating
distance of the infrared beam at approximately 4”. It should
be set so that the white dot on the dial is at 12 o’clock (top
dead center). These settings should not be altered.
5. KM CONTROL TRANSFORMER: The KM control trans-
former supplies 10.5 VAC to the control board through the
K2 connector. This 115V/10.5V stepdown transformer is a
heavy duty component with an internal thermal overload.
The primary winding of this transformer will handle higher
voltage without damage because the thermal overload will
open to protect the winding in the case of improper supply
voltage. The control board monitors the output voltage of
this control transformer and provides automatic reset high
and low voltage protection.
The red LED on the control board will not light if no control
voltage is supplied. The 115V transformer primary circuit is
supplied through the thermostatic bin control, control switch,
high pressure switch, and low pressure switch if included.
If either of these switches are open, there is not control
voltage at the K2 connector and the unit will not operate.
The transformer secondary circuit includes the cleaning
valve interlock switch. If this switch is open, no control
voltage is supplied to the K2 connector so the unit will not
operate. Always check the cleaning valve position and
interlock switch if the red LED is off.
Because of the voltage protection, if the control trans-
former fails, it is important to use the correct OEM part.