Technical information
12/01/02
4. BIN CONTROL:
Checkout for the bin control will vary depending on the
model and control that is used.
a) THERMOSTATIC BIN CONTROL: The thermostatic
bulb is mounted in the ice drop area to sense the ice
buildup. To adjust the bin control, hold ice against the
bulb while the unit is operating. You will find it easier to
place the control switch to the wash position to check
the bin control operation. It is easy to hear the pump
motor stop when the bin control opens. The unit should
shut
down within a 10 second window when the
control is adjusted properly. If this does not occur,
adjust the thermostatic control by turning the screw-
driver slot. Adjusting towards warmer will allow the
unit to shut down quicker. This adjustment should be
checked at installation, when diagnosing a bin control
problem, or if a replacement bin control is installed.
KM 150 / 250 / 280 / 500 / 630 /900 units have a bin
control mounted in the ice drop zone area. KM-1300M /
S and larger units have a drop down bracket that must
be dropped down, secured, and plugged in at installa-
tion. The ice must contact the bulb to operate the
bin control. Some bin applications require an exten-
sion bracket or relocation of the bulb mounting to allow
for proper shut down. Check this positioning if the
control is adjusted properly and ice continues to back
up into the evaporator section. Assure that the exten-
sion bracket is installed.
The symptoms of a bad thermostatic control are:
STUCK CLOSED: The unit continues to operate when the
bin is full. This allows ice to back up in the evaporator
compartment and generally causes a freeze up condition.
This will also occur if the bin control is adjusted too cold or
fully “CW”. Check the adjustment and bulb location before
you diagnose a stuck bin control.
STUCK OPEN: The unit will not start in the ice position. An
easy method to check for an open bin control is to flip the
control switch to WASH. If the pump starts, the bin control
is closed.
b) MECHANICAL BIN CONTROL: The mechanical bin
control uses a moving actuator paddle to open and
44
12/20/03
2/20/03