Technical information

12/01/02
40
COMPONENT CHECKS:
1.FLOAT SWITCH:
Check out the float switch with an ohm meter. When the
float is up, the switch is closed. When the float is down,
the switch is open.
STICKING FLOAT SWITCH:
It is important to remember that the float switch is in the
water circuit and is susceptible to scale buildup. This can
cause the float to stick either up or down. If the float
switch is sticking, it should be cleaned thoroughly with ice
machine cleaner and checked for proper operation. If the
float switch is defective, it should be replaced however, a
dirty float switch is not considered a warranty item.
The symptoms of a sticking float are:
UP/CLOSED: 60 minute freeze cycle, larger cubes,
and pump cavitates prior to harvest.
After 2 consecutive maximum freeze cycles, the
unit will shut down on a 3 beep safety.
To reset this alarm, press the Alarm Reset but
ton on the board with power ON.
DOWN/OPEN: Unit shuts down on low water
safety and water runs continuously.
Heavy scale can be difficult to remove from the float. The
float is available as a replacement part as well as the float
pin. If the housing is defective, replace the complete float
switch assembly.
Replacement Float
# 4A0886F02
Replacement pin
# 4A1141-01
12/20/03
2/20/03