Technical information
12/01/02
“E” Control Board Adjustment Chart
The early “E” boards have 8 dip switches. The latest “E”
boards have 10 dip switches.
NOTE:
1. TO IMPROVE BUILT-IN CLEANING Adjust switches 1&2 to
provide for longer flush and switches 5&6 to every cycle
pump-out 1/1. Do not adjust 1&2 on KM150/250 in high
ambient area.
2. DO NOT ADJUST 3, 4, 7, 8, 9 &10 from factory setting.
3. DO NOT MAKE CONNECTION to the red K-4 terminal
unless a special bin control / red connector is provided.
4. Dip-switches 9&10 are on improved “E” board only. If
original board has 8 dip-swithes, use default setting of
OFF/OFF for 9 & 10. If original board has 10 dip-switches,
match original “E” board settings.
“E” BOARD DIP SWITCH SETTING GUIDE
ADJUSTMENTS DIP # Switch Code
10101
20011
seconds 60 90 120 180
PUMP OUT 3 0 1 0 1
TIME 4 0 0 1 1
seconds 10 10 10 20
seconds 150 180 120 180
status OFF OFF ON OFF
PERIODIC 5 0 1 0 1
PUMP OUT
FREQUENCY 6 0 0 1 1
cycles 1/1 1/2 1/5 1/10
BIN CONTROL 7
OFF for thermostatic contol
SWITCH ON for mechanical control
TEST 8
MAX. FREEZE 9 1 1 0 0
TIME
10 1 0 1 0
(Improved E
board only.)
minutes 75/50hz 70 50 60
ALWAYS OFF
1=ON 0=OFF
Length of pump out
Min Defrost Time
Inlet Water Valve
Default
DEFROST
COMPLETION
TIMER
60/
60hz
19
12/20/03
2/20/03