Technical information

12/01/02
Ambient Temp °F /°C
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
Water Temp
°F /°C
70 / 21
80 / 27
90 / 32
Water
803
770
726
30
30
30
249
249
249
44
44
44
879
851
830
30
30
30
255
255
255
44
44
44
684
645
608
30
32
32
280
280
280
47
47
47
809
789
770
30
30
30
256
256
256
45
45
45
573
567
509
32
32
33
310
310
310
49
49
49
Evaporator
Outlet temp.
(°F )
Pressure
High Side
Pressure
Suction
Kg=lbs.
x .454
Production
24 hours
(lbs.)
751
746
714
30
30
32
256
256
256
45
45
45
100 / 38
480
452
423
33
33
33
346
346
346
52
52
52
697
679
628
32
32
32
614
614
614
47
47
47
MODEL: DCM-750B_ F/H
Total Amperage (Compressor RLA): BAF 16.4 (11A), BWF 14.5A (10A) Supply
Voltage: 115/60/1
Water consumption for water cooled cond: 70/50 (21/9) 421 Gal/24 hr. 90/70 (32/21) 624 Gal/24 hr.
187
Air
WaterAir
Water
Air
WaterAir
R-404A PERFORMANCE DATA
12/20/03
2/20/03