Ambient Temp °F/°C
PERFORMANCE DATA
Evaporator
Outlet temp.
(°F)
Pressure
High Side
Pressure
Suction
Kg=lbs.
x .454
Production
24 hours
(lbs.)
MODEL: F-800M _F / H
Total Amperage (Compressor RLA): MAF 11.95A (9.2A), MWF 10.2A (8.3A)
Supply voltage: 115/60/1
Water consumption for water cooled cond: 70/50 (21/9) 318 Gal/24 hr. 9
0/70 (32/21) 539 Gal/24 hr.
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
WaterTemp
°F/°C
70 / 21
80 / 27
90 / 32
Air Water
Air Water Air Water
800
765
735
17
18
18
223
239
255
35
37
38
720
695
680
21
22
21
265
267
266
37
37
37
710
680
655
19
21
20
270
287
287
39
41
41
670
660
650
38
37
38
630
615
585
21
20
21
286
287
306
41
41
43
640
625
620
21
22
22
266
266
265
38
38
38
100 / 38
Air Water
560
540
505
22
23
22
315
325
325
44
45
45
605
595
555
23
23
22
267
269
268
39
39
39
22
22
22
267
266
265
170
R-404A
12/20/03