CAPACITIVE PROXIMITY BIN CONTROL: (Used on KM-1300NRF/H onl
y)
The capacitive bin control requires DC voltage to operate. It has a seperate 24VDC power supply and switches a control relay to
supply
resistance to the K4 connector. The relay contacts isolates the 24VDC from the control board which switches by resistance.
1. When the bin is empty, the resistance at K4 is 5.6 K Ohms
.
2. When ice is within 1/2 to 1 inch of the sensor end, the resistance at K4 is 15.8 K Ohms to shut the unit down.
115 VAC
24 VDC