Technical information

12/01/02
Note:
All Electrical connections must be made in accordance
with all national and local electrical codes.
Transformer Application
All 208-230V models include a 115V transformer with a
208/230V selector switch. Be sure to select the position
that best matches the incoming voltage prior to supplying
power to the unit. (Voltage from the center tap to case
ground will be 67.5V due to the transformer circuit.)
208/230V models include 115V controls. They require a
115 / 208-230V circuit which has 4 wires including L1, L2,
dedicated neutral, and ground.
If a dedicated neutral is not available or the previous unit
used a 3 wire circuit, (L1,L2, & gnd.) a step-down trans-
former can be used at the unit to provide power to the
115V components. This will save on installation time and
cost if a dedicated neutral is not present.
Transformer # 4A0817-01 or equivalent can be used for
KM models. Transformer # 446240-01 or equivalent can
be used for F-1000 models. The transformer should be
mounted inside the compressor compartment and wired
using the following generic diagram.
11
L1 N L2
BK W BN
Θ
GND. L1 L2
230V 208V
UNIT
12/20/03
2/20/03