User guide
32
Temperature Override Button Disable
The Mira CombiForce 415 incorporates a safety feature which prevents the
temperature override button from being depressed, enabling the user to access a
higher shower temperature. The shower control is despatched from the factory with
the button in the “enabled” position.
The following sequence will allow the installer to “disable” the temperature override
button if required.
1. Ensure the shower control is turned off.
Remove the concealing cap.
2. Locate the plastic temperature override stop.
3. Pull out the temperature override stop and reposition it in the slot adjacent to the
red temperature override button.
4. Reversing the above procedure will “enable” the temperature override button
movement.
Temperature
Override Button
Temperature
Override Stop
Temperature Override
Button Enabled
Temperature Override
Button Disabled