7. Fit the shower control body onto the
backplate and secure by tightening,
clockwise, the two recessed grub
screws, using the 2.5 mm A/F hexagon
wrench (supplied).
8. Refit the elbows in the required position,
i.e. rising or falling supplies. Ensure the
grub screws locate into the 'V' groove
and tighten the grub screws.
9. Assemble the components of the inlet
connector compression fittings in the
following sequence for each inlet:-
9.1. Place the fibre gasket against
the shoulder of the
1
/
2
" BSP
inlet connector nipple.
9.2. Screw, clockwise, the
1
/
2
"
BSP connector nipple into
the elbow ensuring that the
compression taper faces
uppermost, using a 12 mm A/F
hexagon wrench (not supplied).
Rising Supplies
Falling Supplies
Connector
Nipple
Fibre
Gasket
Fibre Gasket
15 mm Compression
1
/
2
" Male BSP
Backplate
Shower Control Body
Grub Screws