Install Instructions

PART NO. 37-6535C
Replaces 37-6535B
0541
F92-1008
Regulated Natural to L.P. Gas
Conversion Kit for 36G/H/J Two-Stage
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
Installer: Save these instructions for future use!
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, explo-
sion, or production of carbon monoxide may result,
causing property damage, personal injury, or loss of
life. The qualified service agency performing the work
assumes the responsibility for the proper conversion
of this appliance with this kit.
APPLICATION
This conversion kit allows the 36G/H/J Series Two-Stage gas
valves to be used on L.P. gas applications. This conversion kit
is for use on all 36G/H/J Two-Stage, fast and slow open
models.
WARNING
!
VALVE CONVERTED FOR USE ON L.P.
GAS. IMPROPER OPERATION COULD
RESULT IN DEATH OR SERIOUS
INJURY.
WARNING
!
SOUPAPE CONVERTIE POUR USAGE
SUR GAZ DE PÉTROLE LIQUÉFIÉ.
UN FONCTIONNEMENT INAPPROPRIÉ
PEUT PROVOQUER LA MORT OU DES
BLESSURES GRAVES.
MISE EN GARDE
!
Figure 3. Contents of kit
WARNING Label
L.P. Regulator
Springs
L.P. Labels
LP LP
Regulator
Cover Screw
Regulator Spring
Plastic Regulator
Adjustment Screw
High
Low
Figure 1. 36G and 36J
2-Stage models
TO CONVERT FROM NATURAL TO L.P. GAS
1. Remove both regulator cover screws.
2. Remove both regulator adjustment screws (beneath the
cover screws).
3. Remove both Natural Gas regulator springs (color-coded
silver/plain) from regulator sleeves.
4. Insert the L.P. regulator springs (provided in the conversion
kit and color-coded white) into the regulator sleeves.
5. Replace the High regulator adjustment screw and adjust
approximately 12 turns to the bottom stop.
6. Replace the Low regulator adjustment screw and adjust
approximately 8 turns.
7. Adjust both outlet pressures to the appliance manufacturer's
requirements.
8. Replace both regulator cover screws.
9. Attach the WARNING label (provided in the kit) to the gas
valve where it can be readily seen. Also attach the small
round L.P. labels to the top of the regulator cover screws.
Conversion back to Natural Gas use may be made at a later
date by retaining the Natural Gas springs (removed in step 3,
above) and following the same procedures.
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
Regulator
Cover Screw
Regulator Spring
Plastic Regulator
Adjustment Screw
High
Low
Figure 2. 36H 2-Stage models