SDS
Section 8. Exposure controls/personal protection
Hand protection
Use a properly fitted, air-purifying or air-fed respirator complying with an approved 
standard if a risk assessment indicates this is necessary. Respirator selection must be 
based on known or anticipated exposure levels, the hazards of the product and the safe 
working limits of the selected respirator.
Chemical-resistant, impervious gloves complying with an approved standard should be 
worn at all times when handling chemical products if a risk assessment indicates this is 
necessary. Considering the parameters specified by the glove manufacturer, check 
during use that the gloves are still retaining their protective properties. It should be 
noted that the time to breakthrough for any glove material may be different for different 
glove manufacturers. In the case of mixtures, consisting of several substances, the 
protection time of the gloves cannot be accurately estimated.
Safety eyewear complying with an approved standard should be used when a risk 
assessment indicates this is necessary to avoid exposure to liquid splashes, mists,
gases or dusts. If contact is possible, the following protection should be worn, unless 
the assessment indicates a higher degree of protection: safety glasses with side-
shields.
Eye/face protection
Respiratory protection
:
:
:
Body protection
Personal protective equipment for the body should be selected based on the task being 
performed and the risks involved and should be approved by a specialist before 
handling this product.
:
Environmental exposure 
controls
:
Emissions from ventilation or work process equipment should be checked to ensure 
they comply with the requirements of environmental protection legislation. In some 
cases, fume scrubbers, filters or engineering modifications to the process equipment 
will be necessary to reduce emissions to acceptable levels.
Appropriate engineering 
controls
:
If user operations generate dust, fumes, gas, vapor or mist, use process enclosures,
local exhaust ventilation or other engineering controls to keep worker exposure to 
airborne contaminants below any recommended or statutory limits.
Wash hands, forearms and face thoroughly after handling chemical products, before 
eating, smoking and using the lavatory and at the end of the working period.
Appropriate techniques should be used to remove potentially contaminated clothing.
Wash contaminated clothing before reusing. Ensure that eyewash stations and safety 
showers are close to the workstation location.
Hygiene measures
:
Individual protection measures
Skin protection
Other skin protection
:
Appropriate footwear and any additional skin protection measures should be selected 
based on the task being performed and the risks involved and should be approved by a 
specialist before handling this product.
Section 9. Physical and chemical properties
Physical state
Melting point
Vapor pressure
Liquid.
Not available.
0.31 kPa (2.333 mm Hg) [at 20°C]
Not available.
Odor
pH
Not available.
Color
Evaporation rate
0.09 (butyl acetate = 1)
Flash point
Closed cup: >93.3°C (>199.9°F)
8.7
Not available.
Odor threshold
:
:
:
:
:
:
:
:
:
Appearance
Boiling point
:
100°C (212°F)
Flammability (solid, gas)
:
Not available.
Lower and upper explosive 
(flammable) limits
:
Lower: 3.2%
Upper: 15.3%
Date of issue/Date of revision
:
11/9/2015
Date of previous issue
:
7/25/2015
Version
:
1.04
5/11