8 INSTALLATION AND SERVICE INSTRUCTIONS Keep this booklet for future reference. The dryer must be fitted by a competent person. In the U.K. Registered Installers undertake to work to safe and satisfactory standards. The dryer must be installed in accordance with the Gas Safety (Installation and Use) Regulations 1998. Guidance may be obtained from the relevant parts of B.S. 7624: B.S. 5440 parts 1 and 2, B.S. 6891: current editions, I.E.E. Wiring Regulations, and relevant Building Regulations.
Contents Page Technical Data . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Service instructions . . . . . . . . . . . . . . . . . . 6 Fault Finding . . . . . . . . . . . . . . . . . . . . . . . . 9 Wiring diagram . . . . . . . . . . . . . . . . . . . . . 14 Exploded views . . . . . . . . . . . . . . . . . . . . .15 Parts list . . . . . . . . . . . . . . . . . . . . . . . . . . .
TECHNICAL DATA GENERAL Front loading resistance sensing tumble dryer with gas heating. Reverse action drum tumble. Electronic control. 2-temperature exhaust thermostat control. Induced air flow enters dryer through front grille, some passes through the gas burner into the rear ducting and some into the cooling passages, this mixed air enters the drum through the rear perforations, passes through the clothes, lint filter, and the fan and is discharged through the vent at the rear.
INSTALLATION 1 INSTALLATION The dryer is designed for installation using a flexible gas connection with tubing in accordance with B.S. 669. Ensure that the supply gas sizing is adequate. When installing, position the appliance so that the plug is accessible. An electric supply cord with moulded-on 13 Amp. plug is fitted at the back of the dryer. The length is 1.5 m. (5ft.). If there are any other appliances that are relatively high rated (eg a central heating boiler) fed from the same gas supply branch.
6. OPERATIONAL CHECK 6.1 Remove the pressure test point screw from the gas tee connection at the back of the dryer and connect a gas pressure gauge. 6.2 Check that the selector switch is set to 'Extra dry', and that the heat switch is set to 'high'. 7 It is most important that airflow to the plinth is not restricted. 8 MAINTENANCE This appliance does not require an annual service unless it is required as part of a landlord's gas safety certificate.
SERVICE INSTRUCTIONS PROGRAMME RECOMMENDATIONS FOR DISMANTLING The electronic control measures dryness by the electrical resistance method and operates relays to: a) energise the drive motor, in foward and reverse rotation and b) energise the full sequence flame controller. Note: Re-assembly should be done in reverse sequence to these instructions.
the Fan Access Cover (447) and the back of the Banjo Assy (440). From underneath the dryer withdraw the 4screws (396) securing the Motor Bracket (432) to the cabinet base. Lift out the Motor and Fan Assy. Special tool (7813 002 61111) is recommended when installing a new belt which needs to be levered and stretched onto the motor spindle (see illustration). HEATER ASSEMBLY REMOVAL Heater Assy. (32), Solenoid Coil (45 or 45A), Flame failure Electrode (33), lgnition Electrode (39).
REAR ACCESS UPPER Rear Seal Assy. (14), Drive Belt (125), Drum (266), Drum Shaft and Bearing (270). Remove the table top assembly (386) and disconnect the Faston terminals from the 2-way Terminal Block (28). Lay the dryer flat on its front supported to take the weight from the door and controls. Withdraw the 6-screws securing the Cover plate (19) and remove it. Pull out the Exhaust Tube (30). Withdraw the 4-screws securing the Hot Air Elbow (20) and remove it.
FAULT FINDING In the event of an electrical fault carry out the preliminary electrical system checks i.e. earth continuity, polarity, and insulation resistance. Use each chart to locate the fault causing the dryer to operate incorrectly as follows: Chart No. 1 Motor does not run. 2 Motor runs but full sequence control does not produce ignition spark. 3 Motor runs, Full Sequence Control produces ignition sparks, but gas does not ignite. 4 Motor runs, gas ignites but burns for only a short period.
Chart 1. Motor does not run START Yes Exchange R.F.I. filter, does motor start? Yes Correct as necessary does motor start? Yes Check fuse and mains cable for continuity, does motor start? Is electrical continuity across both live and neutral paths of R.F.I.
Chart 2. Motor runs but full sequence control does not produce ignition spark START With machine ON (30 min) is voltage between output HE on controller and TB-N 230v? Yes Exchange sensing controller, Does gas control spark? Yes Does control spark with low heat selected? No No Yes No Yes Change 50˚C exhaust thermostat Does control spark? Yes Check continuity of red wire between sensing control HE and heat selector switch. Are connections clean and tight.
Chart 3.
Chart 4. Motor runs, gas ignites but stays on for only short period Before proceeding, ensure polarity of 13 Amp supply socket and earthing is correct.
WHITE KNIGHT ECO 83A_ CROSSLEE P.L.C.
WHITE KNIGHT ECO 83A_ CROSSLEE PLC Exploded View 2 REAR ASSEMBLY VIEWED FROM FRONT 38 144 408 409 410 411 141 28 398 15 16 17 389 375 375 393 143 13 18 375 20 14 23 21 22 412 375 19 24 25 26 27 25 403 396 16
WHITE KNIGHT ECO 83A_ CROSSLEE P.L.C.
WHITE KNIGHT ECO 83A_ CROSSLEE P.L.C.
WHITE KNIGHT ECO 83A_ CROSSLEE P.L.C.
BG83A_ (Eco 83A) PARTS LIST Item 10 11 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 38 39 41 45 101 101a 112 125 141 142 143 144 196 199 201 203 203a 211 213 217 218 219 229 232 235 248 249 250 266 270 352 Description Control Unit Control Unit Bracket Assembly Screw M4 x 10 Rear Seal Assembly External Feed Pipe (Bundy Tube Assy 3) Gas Inlet Connector Restrainer Plate Rear Banjo Cover Plate (access) Hot Air Elbow Assembly Air Channel/lnsulating Plate Assembly Air Guide Cable Clip Back Pane
BG83A_ (Eco 83A) PARTS LIST 353 354 356 359 362 363 364 365 366 367 369 370 372 374 375 376 377 386 387 389 393 394 396 398 403 406 407 408 409 409 410 411 412 427 432 438 439 440 441 442 444 445 446 447 447/1 448 451 454 455 456 458 459 463 464 465 466 Control Panel Assembly Locator Peg 6G*3/8 DP/PWABE/NIBS/TSZPC Hinge Assembly Window Door Frame Latch Pivot Latch Spring Door Latch Switch Strike Loom Clip Latch Guide Timer Bracket Pan Screw St M3 x 5 6 x 3/8 Earth Screw MZP Front Panel Assembly Ellipse Lef
BG83A_ (Eco 83A) PARTS LIST 467 468 477 482 537 552 555 556 Sensing Strip Sensing Strip Clip Ring Spring Plug M4 Toothed Lockwasher W’ Button (access cover) Knob Extension Rear Panels Seal Kit HT Lead Bearing Pads & Brush Seal Kit 4213 075 13152 4213 077 41176 4213 074 81353 2522 616 15007 4213 078 26311 4213 077 59953 4213 092 28001 4213 176 00771 4213 092 21171 4 4 4 5 3 1 2 1 4213 092 54631 4213 092 54641 1 1 PARTS FOR ECO GREEN COLOUR VARIANT 196 376 Cabinet Assy - ECO GREEN Front Panel Assembly
Manufactured By: Crosslee plc, Halifax Road, Hipperholme, Halifax, HX3 8DE 4213 094 79382