User's Manual
78
Advanced Settings
79
To activate Multi-site mode on a Motorola or P25 networked
system:
1. Press PROG to enter Program Mode.
2. Press p, q, t or u to navigate to a talkgroup on the networked
multi-site system.
3. Press
EDIT softkey, then CURR softkey.
4. Press p, q to scroll to the TSYS item and press the SEL key to
edit the TSYS parameters.
5. Press t or u to scroll to Multi-Site.
6. Press t or u to select Off, Stat or Roam.
Off: the scanner will find the first usable control channel in the
control channel list and use it until it is no longer usable.
Stat (Stationary): the scanner will track the system using any
control channel in the list that is usable.
Roam: the scanner will attempt to locate and use the best
possible control channel and ignore others, until the control
channel is no longer usable, then it will locate a new “best
control channel” to use. The scanner will always attempt to lock
on to control channels where the decoding quality is greater
than the Threshold Hi setting, and will search for new control
channels when the decoding quality of a control channel drops
below Threshold Lo setting. If no new control channels are
available that meet the Threshold Hi criteria, the scanner will
seek the best control channel to use, and continue checking
periodically for a new control channel that meets the Threshold
Hi criteria.
7. Press SAVE softkey to save your changes to the TSYS parameters.
8. Press SAVE softkey again to use the scanner.