User's Manual
59
LTR Home Repeater order.
TSYS Menu (Cont.)
L/Out – Permanent lockout status for the object.
Atten – Attenuator, applies 20 dB of attenuation.
Useful in areas with interference from strong
signals.
Narrow FM – Used by most 900 MHz analog
systems. Not used by digital systems.
AudioBoost – 6 dB audio level boost.
Dwell – (0-200 x 100 mS) The time in milliseconds
that the scanner dwells on a Motorola, P25, or
EDACS system control channel. Automatic=0,
which uses control channel information.
Digital AGC – Controls Digital AGC function.
Supertrack – Alternative DSP decoding algorithm.
Multi-Site – Used with networked Motorola and
P25 trunked radio systems.
OFF Uses the first usable control channel in the
control channel list.
STAT Uses every usable control channel in the
control channel list.
ROAM Uses the control channel with the best
decoding quality, lower than Threshold Hi.
Searches for a new control channel when
the current control channel drops below
Threshold Lo.
Threshold Hi
(1-99)
Upper control channel threshold percentage
Threshold Lo
(1-99)
Lower control channel threshold percentage
T Tables – (Default, Splinter, Custom) For
Motorola and P25 systems only.
Fleet Map – For Motorola Type I systems only.