Owners Manual
SC PRO 111519
Page 6 | 1-800-343-9463
Compressor is On
Unit is in Anti-Frost Mode
Fans are On
Alarm is present
Temperature Measurement
CONTROLLER LAYOUT
Refer to page 18 for complete listing of buttons and symbols.
UNIT SPECIFICATIONS
2000 3000 4000
Dimensions 17.5"L x 14.25"W x 15.75"H
Refrigerant R-134a
HP 1/8 1/6 1/6+
Voltage Rating 115V (20-amp dedicated circuit required); 230V (subject to availability)
Weight (lbs) 60 60 60
Amps (running) 3.2 3.7 4.7
Drain Line 1/2" ID clear plastic tubing
Installation Through the wall
Thermostat Advanced digital controller, liquid-temperature-measuring bottle probe
Temp. Delta Can maintain a 55°F cellar temperature with up to 85°F condenser air intake temperature
Outside Venting Not recommended
Warranty Two-year limited warranty (parts and labor) / Five-year limited warranty (compressor)
Menu Navigation
and Value Increase
(Press and hold to manually
enter Anti-Frost mode.)
Power On/O
(hold for approx. 3 seconds)
and Escape
Menu Navigation
and Value Decrease
SET (ENTER)
(Press and hold
to enter the
parameter menu.)
* See note on next page
Contact our sales team if your cellar incorporates stone, concrete, or glass in its construction.