DISPLAY LAYOUT
PLATINUM MINI SPECIFICATIONS
Model
Mini Evaporator Unit
(Fan Coil Unit)
Mini Condenser
(Air-Cooled Condensing Unit)
Cellar Size (cu. ft.) 500
Dimensions 20”w x 10.5”h x 13”d 11.5”w x 8.9”h x 16”d
BTUh with 90°F air enter-
ing the condenser coil.
1730
CFM 99 190
Refrigerant R-134a
Condensing Unit HP 1/6
Voltage Rating 115V (15-amp dedicated circuit required)
Weight (lbs) 25 38.8
AMPS (Starting/Running) 2/1 13.8/3.44
dBA 51 65
Line Set Suction line ⁄” OD; liquid line ¼” OD
Drain Line ½” ID clear plastic tubing (not included)
Installation
Evaporator unit (fan coil unit) is installed in the cellar. The condensing unit is installed up to
100 line feet away and in accordance with the installation specications found in the
technician’s manual.
Thermostat
Digital display
Temp. Delta
55°F temperature dierential
(maintains proper cellar temperature when exhaust environment does not exceed 110°F)
Warranty 2 years (parts and labor)
Compressor is on
Fan is on
Anti-Frost Cycle
running
Alarm is present
°
F
°
F
View/Change Set Point
Enter User Menu
Unlock Button
(hold for 1 sec)
Scroll Button
Change Set Point
55°F
Power On/O
(hold for 5 sec)
Scroll Button
Change Set Point
Return to Previous
Menu