Troubleshooting guide
Page 9
Unobstructed Air ow
Unobstructed air ow to and from
the unit is a critical factor in the unit’s
overall performance. Make sure
there is a 3 ft. horizontal clearance in
the front of the unit. This will assure
that the unit can move the air around
in an e cient manner. Avoid any
attempt to camou age the unit by
installing racking in front of the unit.
This will restrict the air ow and lower
the performance of the unit.
Mounting the Unit
The unit should be mounted within 18“
of the top of the room in order to achieve
su cient cooling. As the room cools down,
the warm air will rise to the ceiling. Mount-
ing the WhisperKOOL high in the room will
create a consistently cool environment by
capturing the warm air and replacing it with
cool air. Mounting the unit low in the room
will result in a temperature variation in the
room due to the unit’s inability to draw
warm air from the ceiling of the cellar to the
unit itself.
Door and Door Seal
An exterior grade (1 3/4”) door must be installed
as a cellar door. It is very important that weather
stripping is attached to all 4 sides of the doorjam.
A bottom “sweep” or threshold is also required.
The door must have a very good seal to keep the
cool cellar air from escaping out of the cellar. One
of the most common problems with cooling units
running continually is the door not sealing prop-
erly. In cases where glass doors are used and the
room size is close to the recommended unit size,
the next larger size WhisperKOOL should be used.
This will compensate for the insulation loss due to
the ine cient door.
T
M
Intake
Exhaust
Front of Unit
Exhaust Room
Wine Cellar