Cutting the Hole for the WhisperKOOL Unit 
Tools Needed 
Sizing the Unit to the Room 
Using a level and a pencil, mark a horizontal line 
on the wall between the two studs, approximately 
1.25” (or as close as possible if more than 1.25”) 
from the ceiling. 
Using a ruler or measuring tape, measure 16” 
down, and mark another horizontal line parallel to 
the  rst one. 
Locate the center of the wall upon which the unit will be installed. Using a stud  nder, locate the studs on 
either side of the center point, and mark them with vertical lines. 
Using a saw, cut along the uppermost horizon-
tal line until your saw reaches the stud. Turn the 
saw around, inserting it into the cut you have just 
made, and cut toward the opposite stud so that 
you have a clean horizontal cut between the two 
studs. Be careful not to cut into the studs them-
selves. 
Now make the second horizontal cut from stud to 
stud on the line 16” below the  rst cut. 
Hammer
Mark the horizontal lines with a level
SawScrewdriver
Level
Model
4000
8000
Cellar Volume
1000
2000
AMP’s
32
36
AMP’s
9
10
Product Dimensions
14.25” x 15.75” x 25.5”
(cubic feet) (starting) (running) (W x H x D)
14.25” x 22” x 27”