Owner's Manual
Page 8 | 1-800-343-9463
WK 2500 081319
WHISPERKOOL SERIES ADVANCED CONTROLLER
Note: The 1 or the 3-5 stands for the amount of time (in seconds) that the button must be held.
Button Functions
ON/OFF • The ON/OFF button turns the refrigeration system on or off. This feature does
notdisconnect power from the unit. The condenser fan will continue to run in the
OFFposition. In order for the power to be shut off from the unit, the power cord must
beunplugged from the wall.
Up and Down
Buttons
• Use these buttons to scroll through the control panel menu.
• These also display the highest and lowest temperature sensed by the bottle probe.
Thisfeature allows the customer instant access to the recorded data applicable to the
bottleprobe temperatures. It can be easily reset to reflect current temperatures.
• Press the “Up” arrow, or the “Down” arrow once, and the highest or lowest
temperature(Hi/Lo) sensed by the bottle probe will be displayed.
• To reset the Hi/Low, press and hold the “Set” button when the Hi/Low value is
displayedon the digital display, continue to hold the “Set” button until “RST” appears on
the digitaldisplay and then blinks. This will erase the past recorded temperature data
history andstart recording from the current time and temperature forward.
Temperatures displayedwould reflect bottle probe temperatures from that point in
time and beyond.
• The Hi/Low feature should be reset at initial start-up and
Cellar Pre-Chill • Activate the Cellar Pre-Chill feature by pressing the “Up” button for 3 to 5 seconds,
andthe CPC logo (a yellow snowflake inside a semi-circle) will be displayed on the
digital display.
Terminate the CPC by pressing the “Up” button again for 3 to 5 seconds or the feature
willself-terminate after 6 hours.
1. The CPC feature may be used to pre-chill the cellar prior to loading it with warm
bottles.The feature will shift the set point down to a lower setting of 52°F for the next 6
hours.After the 6-hour time period, the set point will automatically return to the
original setpoint.
Compressor
Evaporator Fan
Defrost
Energy Reduction
Button 1
Energy Reduction
Set Button
- View set point 1
- Change set point 3-5
- SET + Down = CPSM 5-7
- Reset Hi & Lo Button 3-5
Alarm
Pre-Chill Display
Condenser Fan
Cellar Pre-Chill Button 3-5
High Bottle Temp
History & Scroll Button 1
Low Bottle Temp History
& Scroll Button 1
“ON/OFF” button 1