Technical information

INFORMATION
EN / M-SC6/8/10 / December 2010 15
redundant liquid will be pressed into the expansion tank.
This tank has to be filled up till the mark. When cooling
liquid is not available clean fresh water could be used with
an additive of anti-freeze. When using water with anti-
freeze the right mixture has to be calculated according to
the information of the supplier of the anti-freeze. When the
cooling is based on keel cooling or radiator cooling the
capacity of these coolers and piping has to be taken into
account calculating the right mixture. The cooling liquid in
the engine is pressurised and has a boiling point above
100° C. The temperature switch in the thermostat housing
switches at 110° C. When keel cooling or radiator cooling
is applied the cooling system is not pressurised. There
should be a special cap on the manifold without valves
leaving the connection to the expansion tank open. Refer
to the manual on keel cooling and radiator cooling.
2.5.13 Technical data
Model M-SC6 M-SC8 M-SC10
GENERAL
RPM 3000 3000 3000
Alternator water cooled, synchronous
Engine: Mitsubishi diesel, model L2E L2E L3E
Number of cylinders 2 2 3
Displacement 635 cm3 635 cm3 952 cm3
Bore X stroke 76x70 mm 76x70 mm 76x70 mm
Combustion air consumption 0.9 m3/min 0.9 m3/min 1,4 m3/min
Continuous power engine 5 kW 6,4 kW 10,5 kW
Cooling system indirect cooling by raw water, 10-15 l/min.
Cooling water pump PTO driven WhisperPower self priming impeller pump, type M
Fuel lift pump engine electric pump (12 V DC), additional pump available upon request
Starting battery (optional) 60-90 Ah 12V
Fuel consumption 1.5-4 litre/hour, load dependent
Control Digital Diesel Control including automatic start/stop
ELECTRICAL SPECIFICATIONS
Output voltage 230V 50 Hz alternating current (AC) single phase
Output rating at powerfactor cos phi = 1 5 kW 6,4 kW 9.4 kW
Voltage tolerance ± 5% ± 5% ± 5%
Frequency tolerance ± 5% ± 1% * ± 1% *
Alternator brushless, two pole, synchronous
Voltage regulation: capacitor capacitor + AVR (option) capacitor + AVR (option)
MECHANICAL SPECIFICATIONS
Supply includes generating set, built into tugged GRP sound shield with steel base plate, mounted
on rubber anti vibration mounts
Dimensions hxwxd 660x495x550 mm 660x495x550 mm 810x525x615 mm
Colour top white, bottom green
Weight (including canopy) 178 kg 182 kg; 210 kg
Max. installation angle 25 degrees 25 degrees 25 degrees
Standard supplies remote panel (+15 m cable), fuel lift pump, expansion tank
Optional mobile Installation kits, mobile (vehicle) version, non-earth return, spare part kits
* Electronic governor