16
* Although all of the LEDs may be working properly, there can still be
errors in data transmission. When the signal strength is too high, it can
cause the unit to malfunction during data transmission. Too much
signal strength causes receiver saturation. A temporary solution for
this problem is to slightly pull out the ST connectors approximately
1mm on the modem. Tape the connectors so that they do not fall out,
until a fiber attenuation kit is purchased and installed.