93
Message
: Total maximal duration of delays exceeded in the unit #_.
Explanation
: The number of delay blocks, and their combined delay ranges,
exceeds the maximum capability of this unit. Currently, any single
E Desk unit can provide a maximum of 45 seconds of delay blocks.
Matrix Mixers with Delay also contribute to this total, consuming
1 second per input channel.
Allocation of DSP blocks to DSPs
Message
: Allocating blocks to DSPs...failed to set up a feasible DSP task
schedule in the unit #__. You should move some processing blocks
from this unit into another unit using fixed allocations.
Explanation
: Although the total DSP power in the E Desk unit is sufficient, compile
was not able to distribute the component objects among the
available DSPs. When the DSP load approaches 100%, it becomes
crucial that the objects be distributed more uniformly. Try moving
certain objects to another unit (using fixed allocations), or replace
them with a comparable set of smaller objects (within the same unit).
Otherwise, it may be necessary to add an additional E Desk unit to the
system, and move large DSP blocks into it using fixed allocations.
Assigning control blocks to E Desk units
Message
: Some unconnected control blocks have been ignored.
Explanation
: Control blocks with no connections have been excluded from the
system. Only Logic Gate , Logic Delay, and Remote Preset Button
blocks can be ignored. When connected to the system, control dialogs
for ignored blocks cannot be accessed.
Message
: Feedback detected in the control network.
Explanation
: The potential exists for a control path to be indirectly looped back
upon itself. This condition could be dangerous, and is not allowed.
Message
: Unit #__ has too many control connections.
Explanation
: Although quite large, there is a limit to the quantity of control
connections within a single unit. Connections include both internal
(source and destination within same unit) and external links (source
or destination within this unit). Try moving certain control objects to
another unit (using fixed allocations),