System information
92
Allocation of DSP blocks to Audia Devices
Message
: Too many combinations. Try to reduce the number of groups by
combining DSP blocks.
Explanation
: The possibilities are too numerous to determine a solution within
a reasonable period of time. Reduce the number of groups by
ganging components together or giving them fixed allocations.
Message
: Group #__ has too many connections to be placed into an E Desk
unit.
Explanation
: The specified group requires so many links to other groups that it
would exceed the 'bundle' limitations of CobraNet. Normally, the
number of CobraNet connections could be reduced by combining
the specified group with some other group(s). However, in this case,
it would require more resources than available in a single E Desk unit.
Attempt to produce more compact groups, with fewer connections,
using fixed allocations and/or ganging. This can also happen if
CobraNet I/O blocks have been placed into a non-CobraNet unit.
Message
: Could not place group #__ anywhere. There might be a contention on
group(s)____.
Explanation
: The specified group requires so many links to other groups that it
would exceed the 'bundle' limitations of CobraNet. Normally, the
number of CobraNet connections could be reduced by combining
the specified group with some other group(s). However, in this case,
the number of CobraNet connections cannot be reduced sufficiently.
Message
: Could not find a solution.
Explanation
: Compile was unable to place the produced groups into available
E Desk units. Attempt to use fixed allocations and/or ganging to
change the formation of groups..
Message
: Although the total DSP power is sufficient, the compiler cannot place
the resulting groups into the E Desk units in the Equipment Table.
More units would have to be added.
Explanation
: Compile was not able to distribute the produced groups among the
available E Desk units. This can only occur if the flag 'Auto Device
Add' is not set under Tools>Options>Compile. Attempt to produce
smaller groups using fixed allocations and/or ganging. If
unsuccessful, set 'Auto Device Add' so Compile will automatically
add necessary E Desk units to the Equipment Table. E Desk units can
also be added manually.