System information
123
Meter Blocks
* Can contain a decimal number.
Example: GET 1 RMSMTRLVL 48 1 <LF>
We are asking E Desk the RMS Meter 1 level on instance ID 48.
Generator Blocks
No Attributes are specified at this time
Instance ID Number
E Desk uses an instance ID number to specify the exact DSP block to be controlled. Right click on the DSP block and
select "Properties", the instance number can be found the DSP Attributes 1 tab.
**Note** From the factory the E Desk software will assign an instance number to each DSP block on the initial
Compile of the system. Subsequent compiles will not change the Instance ID Numbers unless the "re-assign Instance
IDs" check box is selected under Compile Options.
If one or more DSP blocks are disconnected from the audio path (when connections are not made to at least one input
or output) the Instance IDs will be unassigned. New Instance ID(s) will be reassigned once the DSP block(s) are
properly connected again.