System information

117
Equalizer Blocks
* Can contain a decimal number.
The Index field represents the filter to be controlled. EQ filter farthest to the left is #1, next one is #2 and so forth.
Upper left hand area of Graphic EQ dialog screen displays, which numbered filter, is being adjusted, use this number
as the Index1 for Graphic EQ strings.
Example: In the string SET 2 GEQBYPALL 9 1 <LF>
We are telling E Desk to bypass all bands on Graphic EQ Instance ID 9.
* Can contain a decimal number.
Upper left hand area of Parametric EQ dialog screen displays, which numbered filter, is being adjusted, use this
number as the Index1 for Parametric EQ strings.
Example: In the string INC 1 PEQLVLBND 11 3 2<LF>
We are telling E Desk to increment the second parametric EQ filter on Instance ID 11 by 2dB.
Example: In the string SET 1 FBSRESET 4<LF>
We are telling E Desk to reset all of the filters on the feedback suppressor on Instance ID 4.