Specifications

8
Figure 7
DRAIN
NOTE: The Start Capacitor and Start Winding of the Drive Motor are energized from P9 during the
Drain Cycle.
NOTE: The Drain Cycle will be interupted when the washer lid is opened.
The drain cycle is activated by applying 120VAC directly to the high speed winding of the drive motor
between Pin P7 (Spin) and Pin P8 (Ag HI) to operate the drive motor through the high speed winding
in the reverse direction.
(Fig. 6)
SPIN
NOTE: The Start Capacitor and Start Winding of the Drive Motor are energized from P9 during the
Spin Cycle.
NOTE: The Spin Cycle will be interupted when the washer lid is opened.
The spin cycle is activated in the same manner as the drain cycle with the exception that there are
three spin speed options which are selected in the OPTIONS list.
Low speed is acheived by applying 120VAC between P14 and P7 to energize the drive motor through
the low speed winding in the reverse direction.
Medium speed is acheived by applying 120VAC between P13 and P7 to energize the drive motor
through the medium speed winding in the reverse direction.
High speed is acheived by applying 120VAC between P8 and P7 to energize the drive motor through
the high speed winding in the reverse direction.
(Fig. 7)
Figure 6
START
HIGH
MED
LOW
DRIVE MOTOR
SPI N P7
AG HI P8
NEUTRAL P10
N/C P11
COMAG P9
L1 P3
COMSPIN P6
LID P4
LLOW P14
LCOM P12
LMED P13
WASHER
CONTROL
ASSEMBLY
LOW P5
SPIN P7
AG HI P8
NEUTRAL
CABINET
GROUND
L1
START
CAPACITOR
CENTRIFUGAL
MOTOR START
SWITCH
START
HIGH
MED
LOW
DRIVE MOTOR
LID
SWITCH