Installation Guide
 26 • Residen al Electric Water Heater Use and Care Guide
TROUBLESHOOTING
WARNING! Working near an 
energized circuit can result in severe 
injury or death from electrical shock. 
WARNING! When you are fi nished, 
be sure all covers are secured to 
reduce the risk of fi re and electric 
shock. 
No Hot Water
The most likely reasons for an electric wa-
ter heater to produce NO hot water are:
• No electric power—a common prob-
lem with new installa ons
• Burned out upper element (Dry 
Fired) — a common problem with 
new installa ons
• Tripped Energy Cut Off  (red bu on 
on upper thermostat)
• The water heater’s inlet and outlet 
connec ons are reversed (usually 
only in new installa ons)
• Broken upper thermostat (or wiring) 
• A leak in the hot water side of the 
plumbing system that exceeds the 
water heater’s hea ng capacity and 
makes it appear that the water heater 
is producing li le to no hot water
Follow these steps to diagnose and 
correct common electrical problems: 
1
Check the electric power to 
the water heater. No hot 
water is o en caused by a 
problem with the home’s electrical 
wiring or circuit breakers. You’ll need a 
non-contact circuit tester. Follow these 
guidelines:
• Locate the water heater’s circuit 
breaker and turn it off  (or remove the 
circuit’s fuses).
• Locate the electrical junc on box on 
top of the water heater and remove 
the cover. 
• Iden fy the two power wires. The 
power wires are usually black/black 
or black/red—the green or copper 
wire is the ground wire. 
• Turn the circuit breaker back on 
(or install the fuses) and check the 
power on both incoming power wires 
using a non-contact circuit tester. 
• Turn the power off  and replace the 
cover on the electrical junc on box. 
If the water heater is not ge ng 
power, contact a qualifi ed person to 
have your home’s wiring or circuit 
breakers checked.
2
Check the upper hea ng 
element. If the water heater is 
ge  ng electrical power, check 
to see if the upper hea ng element has 
burned out. If the upper element is 
burned out, you’ll have no hot water. 
To check the upper element, you’ll 
need a mul meter capable of reading 
resistance.
• Turn the power OFF at the circuit 
breaker or remove fuses. 
• Remove the upper access panel. 
• Remove the insula on to access the 
upper thermostat and hea ng ele-
ment. 
3
Check the top two screws of 
the upper thermostat using a 
non-contact circuit tester and 
confi rm that power is off  (screw 
terminals 1 and 3 in photo on next 
page).
• With the electrical power off , remove 
the two power wires from the upper 
hea ng element. 
4
Check the resistance of the 
upper hea ng element using 
a mul meter. Measure the 
resistance between the two screw 
terminals on the upper hea ng 
element. A good element will have a 
resistance ranging between 5 and 25 
Ohms. If the resistance is: 
Outside this range. Replace the ele-
ment (see the Rou ne Maintenance 
sec on on page 29). On a new water 
heater, a burned out upper hea ng 
element is almost always caused by 
turning the power on before the tank 
was completely full of water (Dry Fire). 
(See Step 8 in the Installa on sec on.)
Within this range. Rea ach the power 
wires, making sure the wires are in 
good condi on and the connec ons 
are clean and  ght. Next, check the 
following:
Use a non-contact circuit tester to check for 
electrical power.
Use a mul meter to check the resistance of the 
upper hea ng element.
TROUBLESHOOTING