Specifications
Electrical requirements
OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Electrical ground is required on this appliance.
A 115 volt, 60 Hz., AC only, 15 or 20 ampere fused electrical supply
is required. (Time delay fuse or circuit breaker is recommended.) It is
recommended that a separate circuit serving only this appliance be
provided. Do not use an extension cord.
DO NOT UNDER ANY CIRCUMSTANCES. REMOVE THE POWER
SUPPLY CORD GROUND PRONG.
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance
must be grounded. This appliance is equipped
with a power supply cord having a 3-prong
grounding plug. To minimize possible shock
hazard, the cord must be plugged into a mating
3-prong grounding type wall receptacle,
grounded in accordance with the National
Electrical Code and local codes and ordi-
nances. If a mating wall receptacle is not avail-
able, it is the personal responsibility and
obligation of the customer to have a properly
grounded 3-prong wall receptacle installed by
a qualified electrician.
TEMPORARY GROUNDING METHOD
If changing and properly grounding the wall
receptacle is impossible and where local
codes permit (consult your electrical inspec-
tor), a temporary adaptor may be plugged into
the existing 2-prong wall receptacle to mate
with the 3-prong power supply cord. THIS
HOWEVER, IS NOT RECOMMENDED.
If this is done, you must connect the ground-
ing eyelet on the adapter to the wall receptacle
cover plate screw and from this same screw,
you must connect a separate copper ground
wire (#14 minimum) to a grounded cold water
pipe.* Do not ground to a gas supply pipe.
Do not connect to electrical supply until
appliance is permanently grounded.
‘Cold water pipe must have metal continuity to electrical
ground and not be interrupled by plastic, rubber or other
electrical insulating connections (including water meter or
pump) without adding a jumper wire at these connections.
I
3PRONG
GROUNDING PLUG
3-PRONG GROUNDING
TYPE WALL RECEPTACLE
POWER SUPPLY CORD
ELECTRICALLY
GROUNDED METAL
COLD-WATER PIPE
(REMOVE PAINT. ETC.)
GROUND ASSEMBLY
\
GROUNDING
PTER
GROUND PRONG
PLUG
POWER SUPPLY CORD
WALL