Setup guide

LC3000 LAUNDRY READER INSTALLATION GUIDE
D OCUMENT 1135 REV 03
PRINTED OCTOBER 6, 2009 1-17
8 Strip back AC wire insulation .28", install wires into AC terminal block
as shown in
Figure 1-13, tighten screws to 5-7 in-lbs., and replace
power supply cover.
Prevent bare wire from being exposed when installed in the AC
terminal block.
UL compliance: Ensure 120VAC wiring is within power supply
compartment when cover is replaced.
9 Position LCM20, component side facing out,
over the six standoffs,
and secure using the
#4-40 screws from the hardware kit.
10 Set rotary address switch to position 1 or 2.
Position 1: machines 21 - 40
Position 2: machines 41 - 60.
11 Route Belden cable from external LCM20 to
LCM20 mounted inside the LC3000
enclosure.
Refer to LCM20 and LE3/PSENCL
Connections (page 1-17) for cable
termination.
12 Route a 4-conductor cable from each laundry
machine to an LCM20 terminal block (TB1 -
TB20).
Consider marking cables uniquely for easy
identification.
Do not connect LCM20 power until all machine interfaces are terminated at both the
laundry machine and the LCM20.
Figure 1-13 Power
Connections
Line
Ground
Neutral
ACMAIN
L N G
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
power
to LCM20 in LC3000
rotary
switch
(set to
1 or 2)
(Belden 5502UE cable or equivalent)
Figure 1-14 LCM20 and LE3/PSENCL
Connections
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F