Setup guide
LC3000 LAUNDRY READER INSTALLATION GUIDE
D OCUMENT 1135 REV 03
PRINTED OCTOBER 6, 2009 1-11
3 Press NEXT when the End of Config Setup message displays, this saves the settings and reboot the
reader.
The terminal may be offline for several minutes until it synchronizes with the Host.
Configure LC3000 Reader using RS-232
4 Connect a cable from a computer’s
serial port to the port on the LC3000
door labelled “RS-232 CONFIG”.
See: RS-232 Config Port Connections
(Page: 11).
5 Open a terminal program (e.g.
Hyperterminal) and establish connection
settings:
• 9600 baud
•1 stop
•no parity
• no flow control
6 Log in using the default password: IPrdr4U.
The password is case sensitive. Consider changing the password.
7 At the prompt, type config and press Enter.
See: LC3000 Laundry Reader Configuration
(page 1-10) for configuration items.
8 When complete, disconnect cable from RS-232
CONFIG.
Configure LC3000 Reader using Telnet
9 Open a Telnet session to the LC3000 Reader’s
IP address.
10 Log in using the default password: IPrdr4U.
The password is case sensitive. Consider changing the password.
11 At the prompt, type the following command and press Enter to start configuration:
config to configure the LC3000. See: Figure 1-6 LC3000 Laundry Reader Configuration (page 10)
for the configuration options.
Figure 1-8 LC3000 Configuration Menu
IPrdr4U
Table 1-1: RS-232 Config Port
Connections
Signal
LC3000
(RJ-12)
PC Serial Port
DB9 Connector
Ground Pin 1 Pin 5
Receive (RX) Pin 3 Pin 3
Transmit (TX) Pin 4 Pin 2