Setup guide

LC3000 LAUNDRY READER INSTALLATION
PRINTED OCTOBER 6, 2009
1-6
LC3000 LAUNDRY READER INSTALLATION
The LC3000 Laundry Reader must be mounted on a wall in a location that is convenient to cardholders
and wiring requirements.
LC3000 MOUNTING LOCATION CONSIDERATIONS
120 VAC power availability
Connect to 120 VAC @ 60 Hz. Connect only to a 15A maximum branch circuit protection or equivalent.
Use a circuit breaker or switch to disconnect power when installing or removing the LC3000.
Network communications availability (RS-485 or 10/100 Base T)
Wiring distance limitations
- RS-485 Communications 4000' total per loop
- 10/100 Base-T Communications 300' from the network switch port
Ease of cable routing to laundry machines (if wired configuration)
Installation height regulations
Cardholder convenience
Mounting hardware required: .25” appropriate to surface.