User Manual Part 1
21
Replacing Filters
The grease filters should be removed and cleaned at least once a
month. Do not operate the oven without the grease filters in
place. The 3M FILTRETE™ charcoal odor filter cannot be cleaned
and should be replaced every 6 to 12 months, or as prompted by
oven. To order replacement filters, call 1-800-4-MY-HOME
®
. See
“Replacement Parts” section for part numbers.
3M FILTRETE™ CHARCOAL ODOR FILTER
This filter works with the exhast fan to eliminate cooking odors.
Depending on the fan speed used, the life of the filter ranges from
50 hours to 100 hours.
The Odor Filter Status screen, available through the Options
menu (see “Options” section), shows the percentage of the filter
usage, from 0% (new) to 100% (needs changing). When the
usage reaches between 90-95%, and the fan button is pressed,
the Order Filter screen appears on the display with ordering
information and changing instructions.
To Remove and Replace:
1. Open oven door.
2. Tilt vent grille forward and lift out to remove.
3. Lift filter up, then pull it out of the slot.
4. Replace the 3M FILTRETE™ charcoal odor filter by
positioning the new filter in the slot. “This side out” printed on
the edge of the filter should be facing out. Then replace the
vent grille by aligning the bottom tabs and snapping it back
into place.
GREASE FILTERS
To Remove and Replace Grease Filters:
1. Unplug oven or disconnect power.
2. Remove each of the grease filters by pushing the back of the
filter up, grasping the tab, and sliding the filter to the back.
Pull tab down until the filter drops out.
3. Replace grease filters by inserting the end without the tab
into the frame. Swing other end up and slide into position.
4. Plug in oven or reconnect power.
Replacing Cooktop Light
The cooktop light is a 10W low-voltage halogen capsule bulb. To
order replacement parts, call 1-800-4-MY-HOME
®
. See
“Replacement Parts” section for part number.
To Replace:
1. Unplug oven or disconnect power.
2. Remove bulb cover mounting screw, and carefully remove
cover.
3. Remove the burned-out bulb.
4. Replace bulb, using a tissue to handle the bulb, or wearing
cotton gloves. Do not touch bulb with bare fingers.
5. Replace bulb cover and mounting screw.
6. Plug in oven or reconnect power.
WARNING
Electrical Shock Hazard
Disconnect power before removing filters.
Replace all panels before operating.
Failure to do so can result in death or
electrical shock.