Installation Instructions

- 3 -
150cm.
The lock is locked.
surface of the LF antenna
within 230cm~260 cm, and
press the power button
again.
2. After counting 2 seconds, press
Power Button to perform locking
action.
3. The system performs lock, and
the buzzer sounds for 500ms.
4.Red LED light up for 2 seconds.
5. Extinguish the blue LED.
8
HOST
Identificaton
fail(Antenna)
Power input 12V±0.1V
Place the smart key within
the surface of the LF antenna
150cm.
Identification first, after the
system is unlocked.
Place the smart key outside
the surface of the LF
antenna 300cm.
1. Identification after every 3
seconds of counting.
2.Identification failed, system
execution lock
3. The buzzer sounds for 500ms.
4. Red LED light up for 2 seconds.
5. Extinguish the blue LED.
9
HOST
Lock(Antenna)
Power input 12V±0.1V
Change IGN OFF/IGN OF2
Switch to IGN ON.
1.System execution lock.
2.The blue LED will slowly light
up.
10
HOST
Lock
Power input 12V±0.1V
Place the smart key surface
of the LF antenna
within150cm~300 cm.
If the turntable is pressed,
touch the positioning signal
Pull Low.
The system cannot perform
locking.
11
HOST
Lock
Power input 12V±0.1V
Place the smart key within
the surface of the LF antenna
150cm.
1.Power Bottom pressed
300ms
2. Positioning signal Pull
Low.
1.Red LED ON/OFF
(500ms/500ms)continued 10
seconds.
2.Buzzer sound ON/OFF
(500ms/500ms)continued 10
seconds.