Instruction manual
3-25
Table 3-4
Standby Current for Dual-Circuit SAFEPATH
®
Panel
Model
Standby Current
per UL Full Power
SIN Wave Testing
1
Standby Current
when DCDC is in
Temporal Code 3
Tone
2
Standby Current
when DCDC is in
HI/LO
3
(Worst Case
Tone)
DCSP-4RP
0.630 Amps
0.530 Amps
0.530 Amps
DCSP-4RP + SAA-40S
1.030 Amps
0.830 Amps
0.830 Amps
DCSP-4RP + SAA-80S
1.230 Amps
0.830 Amps
0.930 Amps
DCSP-4RP + SALL-15S
0.730 Amps
4
0.630 Amps
4
0.630 Amps
4
DCSP-8RP
0.830 Amps
0.530 Amps
0.630 Amps
DCSP-8RP + SAA-40S
1.230 Amps
0.830 Amps
0.930 Amps
DCSP-8RP + SAA-80S
1.430 Amps
0.830Amps.
1.030 Amps
DCSP-8RP + SALL-15S
0.930 Amps
0.630 Amps
0.730 Amps
DCSP-15SP
0.330 Amps
0.330 Amps
0.330 Amps
DCSP-15SP + SAA-40S
0.730 Amps
0.630 Amps
0.630 Amps
DCSP-15SP + SAA-80S
0.930 Amps
0.630 Amps
0.730 Amps
DCSP-15SP + SALL-15S
0.430 Amps
0.430 Amps
0.430 Amps
1
The UL Test is performed with the amplifiers out of the Panel and in a bench test condition.
2
This column uses the standard current calculation when Temporal Code 3 is selected on the
Control Module (DCDC). This is the recommended configuration for operation.
3
This column shows the current value of the Panel with the Control Module configured on the
highest current reading (HI/LO).