Installation guide
- 2 - AL602ADA220J
Input:
• Powerinput220VAC50/60Hz,1.2amp.
• Two(2)ClassA,StyleZortwo(2)ClassB,
StyleW,X,YFACPinputs.
• Two(2)NCdrycontacttriggerinputs.
Output:
• 24VDC@6.5ampmaxtotalalarmcurrent.
• 2.5ampmaxcurrentperoutput.
• Separate1.0ampauxiliaryoutput.
• Two(2)outputsmaybeparalleledformorepoweronan
indicatingcircuit(see Application Guide).
• Programmablesupervisedindicatingcircuitoutputs:
Four(4)ClassB,StyleW,X,YorTwo(2)ClassA,
StyleZorOne(1)ClassA,StyleZandTwo(2)ClassB,
StyleW,X,Y(see 02 Application Guide).
•Thermalandshortcircuitprotectionwithautoreset.
Battery Backup:
•Built-inchargerforsealedleadacidorgeltypebatteries.
•Automaticswitchovertostand-bybatterywhen
ACFails.
• Zerovoltagedropwhenswitchingoverto
batterybackup.
Supervision:
•ACfailsupervision(form“C”contact,1amp/28VDC).
Factorysetfor30secondswithoptional2.5to3hour
delaysetting(fieldselectable).
• InstantlocalACtroublereportingrelay
(form“C”contact,1amp/28VDC).
•Batterypresenceandlowbatterysupervision
(form“C”contact,1amp/28VDC).
Visual Indicators:
•InputandoutputstatusLEDindicators.
Special Features:
• 2-wirehorn/strobeSyncmodeallowsaudible
notificationappliances(horns)tobesilenced
whilevisualnotificationappliances(strobes)
continuetooperate.
• SyncprotocolsincludePotter/Amseco,Faraday,
Gentex
®
,
SystemSensor
®
,andCooperWheelock
®
.
• TemporalCode3,SteadyMode,InputtoOutput
FollowerMode(maintainssynchronizationof
notificationappliancescircuit).
• Compatiblewith24VDCfirepanels.
•Outputloopsupervisionsteeredtoinput1orinput2.
• Signalcircuittroublememory(helpsidentify
intermittentloopproblems).
• Commontroubleinputandoutputforexternaltrouble
signalstie-in.
• Groundfaultdetection.
•Unitincludespowersupply,redenclosure,camlock,
andbatteryleads.
Enclosure Dimensions (approx. H x W x D):
18”x14.5”x4.5”(457.2mmx368.3mmx114.3mm).
Overview:
The Altronix AL602ADA220J is an extremely cost effective 6.5 amp remote power supply/battery charger. It may be
connectedtoany24voltFireAlarmControlPanel(FACP).PrimaryapplicationsincludeNotificationApplianceCircuit
(NACsuchasstrobesandhorns)expansionsupporttomeetADArequirements.Italsoprovidesauxiliarypowertosupport
systemaccessories.Theunitdeliverselectronicallyregulatedandfiltered24voltpowertoClassB,StyleW,X,YorClass
A,StyleZNACloopcircuits.Additionally,aseparate1.0Aauxiliaryoutputforfour(4)-wiresmokedetectorsisavailable.
The6.5ampmax.alarmcurrentcanbedividedbetweenthefour(4)outputsforpoweringNACdevices.Eachoutputis
ratedat2.5ampmax.,andcanbeindependentlyprogrammedforSteady,TemporalCode3orStrobeSynchronization.All
outputsmaybeprogrammedforInputtoOutputFollowerMode(outputwillfollowinput.i.e.MarchTimeInput,March
TimeOutput).Anindividual outputof4 ampisachieved byparalleling2outputs.In non-alarmconditionindependent
loopsupervisionforClassA,StyleZand/orClassB,StyleW,X,YFACPNACcircuitsisprovided.Intheeventofaloop
trouble,theFACPwillbenotifiedviathesteeredinput(input1orinput2).Inaddition,therearecommontroubleoutput
terminals(NC,C,NO)whichareusedtoindicategeneralloop/systemtrouble.Acommontroubleinputisprovidedfor
optionalNC(normallyclosed)devicestoreporttroubletotheFACP.Two(2)FACPsignalingoutputscanbeemployed
anddirectedtocontrolsupervisionandpowerdeliverytoanycombinationofthefour(4)outputs.
Specifications:
AL602ADA220J - NAC Power Extender
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to all local codes.