Instruction Manual
WHEATHEART - GRAIN AUGERS 3. ASSEMBLY
X160-85, X160-105, X160-125
30875 R0 77
a. For X160-85 models, route the hoses across the backarm bracket to the
opposite side of the auger tube, then to the hydraulic hose catch on side of
auger tube.
b. For X160-105/125 models, route the hoses to the hydraulic hose catch on
side of the auger tube.
7. Tighten hydraulic hose catch snugly enough to hold hoses in place (see
Figure 3.34).
8. Run both hoses straight down the side of the auger to the ball valve location
on the boot, fastening the hoses at each available hose catch.
Important: Protect hose ends from dirt.
9. Recheck that bolts on undercarriage, lift cylinders, and cable clamps are
tight, then remove auger tube support.
10. At the boot, install the ball valve on the hose, and secure the valve to the
boot using the ball valve bracket and two 1/4” x 3/4” bolts and locknuts (see
Figure 3.35).
Figure 3.30 Lift Cylinder Hydraulic Hoses and Fittings (X160-85)
P
R
E
S
S
U
R
E
H
O
S
E
F
L
U
I
D
R
E
T
U
R
N
H
O
S
E
C
Y
LIN
D
E
R
1
C
Y
L
I
N
D
E
R
3
CY
L
I
NDE
R
2
U
P
P
E
R
E
N
D
(
D
I
S
C
H
A
R
G
E
)
(ROD END)
(CAP END)
L
O
W
E
R
E
N
D
(
I
N
T
A
K
E
)