Instruction Manual
WHEATHEART - GRAIN AUGERS 7. MAINTENANCE AND STORAGE
X160-85, X160-105, X160-125
30875 R0 127
7.3.2. HYDRAULIC HOSE AND COUPLER INSPECTION
Using a piece of cardboard or wood, run it along the length of the hose and
around all fittings. Replace the hose or tighten/replace the fitting if a leak is
found.
7.3.3. MACHINE GREASING
Important: Most original equipment bearings used are sealed units that do not accept
grease.
The following grease fittings on the machine should be greased regularly:
• one fitting on each frame pin
• seven on the PTO (Figure 7.1)
• six on the intake hopper, u-joints and bearings (Figure 7.2)
• one at the upper flighting bearing (Figure 7.3)
• two on the gearbox coupling shaft (Figure 7.4)
WARNING
High-pressure hydraulic fluid!
Escaping oil under pressure can penetrate
the skin and cause serious injury.
• Relieve pressure on system before repair-
ing, adjusting, or disconnecting.
• Keep connections tight and components
in good repair.
• Use a piece of wood or cardboard when
searching for leaks. DO NOT use your
hand.
• Seek medical attention immediately if
ANY hydraulic fluid penetrates your skin.
NOTICE
Replacement hose and hose ends must have a minimum
strength of 2500 psi (17200 kPa) working pressure.