Instruction Manual

WHEATHEART - GRAIN AUGERS 7. MAINTENANCE AND STORAGE
X160-85, X160-105, X160-125
30875 R0 127
7.3.2. HYDRAULIC HOSE AND COUPLER INSPECTION
Using a piece of cardboard or wood, run it along the length of the hose and
around all fittings. Replace the hose or tighten/replace the fitting if a leak is
found.
7.3.3. MACHINE GREASING
Important: Most original equipment bearings used are sealed units that do not accept
grease.
The following grease fittings on the machine should be greased regularly:
one fitting on each frame pin
seven on the PTO (Figure 7.1)
six on the intake hopper, u-joints and bearings (Figure 7.2)
one at the upper flighting bearing (Figure 7.3)
two on the gearbox coupling shaft (Figure 7.4)
WARNING
High-pressure hydraulic fluid!
Escaping oil under pressure can penetrate
the skin and cause serious injury.
Relieve pressure on system before repair-
ing, adjusting, or disconnecting.
Keep connections tight and components
in good repair.
Use a piece of wood or cardboard when
searching for leaks. DO NOT use your
hand.
Seek medical attention immediately if
ANY hydraulic fluid penetrates your skin.
NOTICE
Replacement hose and hose ends must have a minimum
strength of 2500 psi (17200 kPa) working pressure.