User Manual

WHEATHEART - X13 SERIES AUGERS 3. ASSEMBLY
X1374, X1384, X1394 3.10. AUGER TUBE TRUSS ASSEMBLY
30787 R1 35
3.10. AUGER TUBE TRUSS ASSEMBLY
X130-74 augers use a double cable truss on the top of the auger tube “X130-
74 Auger Tube Truss Assembly” on page 35).
X130-84 and X130-94 augers use a combination of rigid tube trussing on top
of the auger tube and cable trussing on the sides of the auger tube (see
“X130-84/X130-94 Auger Tube Truss Assembly” on page 40).
3.10.1. X130-74 AUGER TUBE TRUSS ASSEMBLY
INSTALL THE X130-74 CABLE BRIDGES
See Table 3.7. for a list of parts required to install the X130-74 cable bridges.
See Figure 3.12 for a detailed diagram.
1. Fasten the three truss towers to the provided brackets (welded to the
appropriate tube sections):
a. Position the high truss tower in the centre position, and position the low
truss towers toward the spout and intake ends.
b. Use two 7/16” x 1-1/4” GR8 bolts and 7/16” locknuts to fasten each cable
bridge in place.
2. Install the truss cable attach bracket as shown in the diagram, using two
7/16” x 1-1/4” GR8 bolts and 7/16” locknuts.
Table 3.7. Parts Required, Installing X130-74 Cable Bridges
Part Number Description Amount
20017 High truss tower
1
18988WH Low truss towers
2
20105 Truss cable attach bracket
1
18698 7/16” x 1-1/4” GR8 bolts
8
17593 7/16” locknut
8