24 30662 R1
6. Insert other end of truss cable through this eyebolt. Pull out all slack and
secure with 2 cable clamps.
7. Tighten eyebolts to take remaining slack out of truss cable and to maintain
the appropriate upward bow. After tension is adjusted, tighten cable clamps
on truss support brackets and upper truss anchor. Check for proper side
alignment.
Important: Once auger is fully assembled, adjust truss cables on all units (because of initial
stretching). Cables may also require adjustment for side alignment.