Owner's manual

3. ASSEMBLY WHEATHEART - SA FLEX AUGER
3.13. HYDRAULICS (71’–91’) 71’ - 111’
56 30651 R5
3.13.2. HYDRAULIC CYLINDER PLUMBING
Note: Refer to Appendix for hydraulic fitting tightening specifications. Use pipe sealant
on all joints. See Table 3.4 for the proper hose length.
1. Remove plugs from the hydraulic cylinder.
2. Install elbow (2) into cylinder port.
3. Attach tee (4) to cylinder port. See Figure 3.39.
4. Attach the hydraulic hose end (5) to tee (4) (Figure 3.39).
5. Install hydraulic hose 3/8” x 2’ (1).
6. Lay the hose (8) (Figure 3.39) along the upper scissor and tube (Figure
3.40).
7. Secure the hydraulic hose along the top of the upper scissor and on the tube
using the welded hose clips.
8. Provide slack or a loop between each secured point.
9. Bend tops of welded clips over slightly to retain hose.
Important: Do not make bends in hydraulic hose too tight. The bends must have a radius of
at least 4” to prevent failure of the hose.
10. Install the ball valve (6), coupling (3), and optional pioneer tip (7) on the
hydraulic hose end (5) (Figure 3.39).
Figure 3.39
Table 3.4
Auger Hose Length
71’ 53’
(16.2 m)
81’ 58-1/2’
(17.8 m)
91’ 67’
(20.42 m)