Manual
4. OPERATION WHEATHEART - SA AUGERS
4.2. OPERATOR CONTROLS SA 1061, 1071, 1081, 1091, 1371, 1381, 1391
20 30582 R7
4.2. OPERATOR CONTROLS
The hopper winch is located as shown in Figure 4.1. The hydraulic shut-off valve
is located as shown in Figure 4.2. Please refer to the tractor manual for hydraulic
and PTO controls.
4.3. PRE-OPERATION
4.3.1. CHECKLIST
• Tighten all fasteners.
• Adjust and/or lubricate boot chain and hopper chain.
• Ensure auger rotates freely.
• Check that tire pressure is within the manufacturer’s specification.
• Ensure wheel bolt torque is within specification .
• Check hopper winch cable for damage (fraying, kinking, unraveling). Replace
as required.
• Ensure cable anchor on the winch drum is tight.
• Check gearbox oil levels.
• Grease and clean machine if needed.
• Ensure hydraulic system is functioning, is free of leaks, and the hoses are not
pinched or kinked.
• Check that truss cables are free from damage (fraying, kinking, unraveling).
The cables must be tight and properly adjusted for proper auger tube align-
ment.
• Ensure PTO shaft is properly installed.
Figure 4.1 Winch Location
Figure 4.2 Shut-off Valve