Owner's manual

6. MAINTENANCE WHEATHEART - R SERIES AUGERS
6.2. MAINTENANCE INTERVALS R8-36, R8-41, R8-46, R8-51, R10-36, R10-41, & R10-51
30 30758 R1
6.2. MAINTENANCE INTERVALS
Refer to Section 6.3. for details of service.
6.3. MAINTENANCE PROCEDURES
6.3.1. VISUAL INSPECTION
Before beginning the visual inspection, chock auger wheels and ensure that all
operators are aware of safety precautions.
When inspecting look for possible defects, and the following:
Ensure all guards are in place, and in good working order.
Examine the auger for damage or unusual wear.
Inspect the machine for evidence of oil leaks.
Examine hydraulic hoses and fittings for leaks and cracks.
Be sure all safety decals are in place and are legible.
Check that drive belts are not frayed or damaged. Ensure they are prop-
erly adjusted and aligned.
Table 6.1 Maintenance Intervals
Time Period
Maintenance Procedure
Daily (8000)BU
Periodically (40,000)BU
Annually (Before Storage)
Annually (After Storage)
Visually Inspect the Unit 6.3.1. X
Check engine oil level 6.3.7. X
Service PTO Driveline 6.3.11. X
Check Air Filter 6.3.7. X
Service Upper Chain Drive 6.3.2. X
Service Belts 6.3.13. X
6.3.14.
Grease Machine 6.3.3. X
Check Gear Box Oil Level 6.3.8. X
Check Winch 6.3.12. X
Clean Machine 6.3.4. X
Service Engine 6.3.7. X
Repack Wheel Bearings 6.3.5. X
Tighten Wheel Bolts 6.3.6. X
Change Gear Box Oil 6.3.9. X
Service Truss Cables (R 851 only) 6.3.10. X