Manual

WHEATHEART - LIVESTOCK WATERER 6. TROUBLESHOOTING
MODELS: H50, H50L, EH50, EEFH50, SH50, ESH50, C50, EC50, C100, EC100, C200, EC200
IM11 R1 21
6. Troubleshooting
6.1. HEAT PROBLEMS
CAUTION
Power must be turned off at breaker box
before waterer is serviced.
WATER FREEZES IN PAN
Cause Solution
Thermostat malfunction.
Ensure there is power to thermostat, or if necessary,
replace thermostat.
Thermostat may not positioned prop-
erly against pan surface.
Ensure heat-sensitive side of thermostat is completely
flush with the pan.
Faulty heating element/pad.
Ensure element/pad is functioning. Check for power
coming into the element/pad.
Too much heat loss from inside
waterer box.
Ensure inspection door is properly insulated and posi-
tioned and the pan is properly seated. Make sure the
base of the waterer box is sealed with weather-strip-
ping or caulking.
WATER OVER-HEATING IN PAN
Cause Solution
Thermostat is unable to sense water/
pan temperature.
Ensure thermostat is flush with bottom of pan surface.
Thermostat is touching the pan, but it is
still overheating.
Replace thermostat.