Datasheet

Table Of Contents
PN532_C1 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.6 — 28 November 2017
115436 146 of 222
NXP Semiconductors
PN532/C1
Near Field Communication (NFC) controller
8.6.23.3 CIU_Command register (D1h or 6331h)
Starts and stops the command execution.
Table 178. CIU_Command register (address D1h or 6331h) bit allocation
Bit 7 6 5 4 3 2 1 0
Symbol - - RcvOff Power-down Command
Reset 001 0 0000
Access RRR/WDY DYDYDYDY
Table 179. Description of CIU_Command bits
Bit Symbol Description
7 to 6 - Reserved
5 RcvOff Set to logic 1, the analog part of the receiver is switched off.
4 Power-down Set to logic 1, the CIU Power-down mode is entered. This means, internal
current consuming blocks of the contactless analog module are switched
off, except for the RF level detector.
Set to logic 0, the PN532 starts the wake up procedure. During this
procedure this bit still shows a logic 1. A logic 0 indicates that the PN532 is
ready for operations; see Section 8.6.19.2 “
CIU Power-down” on page 132.
Note: The Power-down bit can not be set, when the SoftReset command
has been activated.
3 to 0 Command Activates a command according the Command Code.
Reading this register shows, which command is actually executed. See
Section 8.6.20 “
CIU command set” on page 133