Technical Manual
Table Of Contents
- 0. Safety Precautions
- 1. Introduction
- 2. Function of the Coin Selector
- 2.1. Introduction
- 2.2. Programming Connector
- 2.3. Programming of Coins
- 2.4. Coin Selector Output Signals
- 2.5. Coin Blocking
- 2.6. Currencies and Coins
- 2.7. Slave Channels
- 2.8. Coin Return
- 2.9. Safety Features
- 2.10. RFID Card Reader Functionality EMP 500 v7 /CLB
- 2.10.1. Install whcashless App
- 2.10.2. Creation of an Operator Account
- 2.10.3. Setting the Identity of a Coin Selector
- 2.10.4. Getting multiple Operator Keys
- 2.10.5. Setting the Price(s) of a Coin Selector
- 2.10.6. Setting the Price with a Price Setting Key
- 2.10.7. Personalize a CLB Pay Key
- 2.10.8. Loading CLB Pay Key with funds via PayPal
- 2.10.9. Use the CLB Pay Key
- 2.11. Bluetooth Functionality
- 3. The EMP 500 v7 /CLB with Interface 06 – 1 Price Totalizer
- 4.
- 4. Serial Interface
- 5. RS232 Interface
- 6. Coin Selector Label
- 7. Maintenance
- 8. EC Conformation Declaration
- 9. Compliance Statements FCC / ISED for EMP 500 v7 /CLB
- 10. Appendix
- 11. Applications
Technical Manual EMP 500 v7 /CLB WH Münzprüfer Dietmar Trenner GmbH, Germany
version 2.7
page 62/62 subject to technical modification EMP 500 v7 /CLB
Example 2: Washer
present application: mechanical dual selector with micro switch, e.g.
model: SF03.2-W-A-S /-W-A-S for 0.20 and 1.00 British Pound Sterling
future application: electronic coin selector, e.g. model:
EMP 500 v7 /CLB with interface 04 /E/T with front plate F 503 for the
acceptance of British Pound Sterling and Euro as well as two tokens for
on-site programming.
Programming
pulse length: 50 ms pulse pause: 100 ms
coins
blocking switch no.
wide
mid
narrow
number of
pulses
output line
notes
0.10 GBP
1
2
1
1
total blocking of GBP
via switch number 14
0,20 GBP
1
2
2
1
0,50 GBP
1
3
5
1
1.00 GBP
4
5
6
10
1
2,00 GBP
4
5
7
20
1
STD-118-1 (.880)
15
1
1
teach mode channel
0,10 EUR
9
10
1
2
total blocking of EUR
via switch number 13
0,20 EUR
9
10
2
2
0,50 EUR
9
10
5
2
1,00 EUR
9
11
10
2
2,00 EUR
9
12
20
2
STD-118-5 (.990)
16
1
2
teach mode channel