Fig. 23 Connecting diagram EMP 500 v7 /CLB with interface 04
Fig. 24 Connecting diagram EMP 500 v7 /CLB with interface 12
coin 1 (normally open), blue
coin 2 or Inventory (normaly open), grey
35 V DC, 20 mA
option
+ -
~
~
12
4
3
2
1
4
3
PC814
1
2 3
4
PC814
1
2 3
4
GND
GND
GND
GND GND
main blocking, orange
12 to 24V AC/DC, black
8
3
7
4
1
5
2
6
EMP 500.04
power supply, 12 to
24 V AC/DC,
0,6 W / (4,5 W *)
I > 0,5 mA AC/DC
35 V DC, 20 mA
*) approx.. 100 msec. during coin acceptance
12 to 24V AC/DC, black
control
main blocking, orange
coin 2 or inventory (normaly open), violet
coin 1 (normally open), green
coin 1 (normally closed), white
coin 2 or inventory (normally closed), brown
option
+ -
~
~
12
4
3
PC815
1
2 3
4
2
1
4
3
PC815
1
2 3
4
GND
GND
GND
GND
GND
8
7
3
main blocking, orange
4
12 to 24V AC/DC, black
1
35 V DC, 30 mA
5
2
6
12 to 24V AC/DC, black
*) approx. 100 msec. during coin acceptance
power supply, 12 to
24 V AC/DC,
0,6 W / (4,5 W *)
35 V DC, 30 mA
main blocking, orange
EMP 500.12 control
I > 0,5 mA AC/DC
coin 2 or inventory (normally closed), yellow
coin 1 (normally closed), red