Technical Manual

Table Of Contents
WH Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 500 v7 /CLB
version 2.7
EMP 500 v7 /CLB subject to technical modification page 51/62
4.4.2. Assigning MDB Error Codes to ccTalk Error Codes
MDB
Remarks
ccTalk
Remarks
$90
Coin return button
pressed
254
Coin return button
pressed
$91
Subsequent coin
8
Subsequent coin
$92
Coin jam 1
19
Coin too slow
$93
Coin does not match
parameter set
1
Coin rejected
$94
MDB blocking
2
Coin blocked
$95
Coin jam 2
19
Coin too slow
$96
DIP switch blocking
2
Coin blocked
$97
Coin jam 3
19
Coin too slow
$98
Coin jam 4
19
Coin too slow
$99
Coin jam 6
19
Coin too slow
$9A
Rim detection error
1
Coin rejected
$9B
Lead detection
1
Coin rejected
$9C
Old: coin following to
closely in TCAP1
255
Unknown error
$9D
Coin-on-a-thread
detection
20
Coin on a thread
manipulation
$9E
General blocking
2
Coin blocked
$9F
EMP busy
13
Not ready