Technical Manual
Table Of Contents
- 0. Safety Precautions
- 1. Introduction
- 2. Function of the Coin Selector
- 2.1. Introduction
- 2.2. Programming Connector
- 2.3. Programming of Coins
- 2.4. Coin Selector Output Signals
- 2.5. Coin Blocking
- 2.6. Currencies and Coins
- 2.7. Slave Channels
- 2.8. Coin Return
- 2.9. Safety Features
- 2.10. RFID Card Reader Functionality EMP 500 v7 /CLB
- 2.10.1. Install whcashless App
- 2.10.2. Creation of an Operator Account
- 2.10.3. Setting the Identity of a Coin Selector
- 2.10.4. Getting multiple Operator Keys
- 2.10.5. Setting the Price(s) of a Coin Selector
- 2.10.6. Setting the Price with a Price Setting Key
- 2.10.7. Personalize a CLB Pay Key
- 2.10.8. Loading CLB Pay Key with funds via PayPal
- 2.10.9. Use the CLB Pay Key
- 2.11. Bluetooth Functionality
- 3. The EMP 500 v7 /CLB with Interface 06 – 1 Price Totalizer
- 4.
- 4. Serial Interface
- 5. RS232 Interface
- 6. Coin Selector Label
- 7. Maintenance
- 8. EC Conformation Declaration
- 9. Compliance Statements FCC / ISED for EMP 500 v7 /CLB
- 10. Appendix
- 11. Applications
Technical Manual EMP 500 v7 /CLB WH Münzprüfer Dietmar Trenner GmbH, Germany
version 2.7
page 12/62 subject to technical modification EMP 500 v7 /CLB
2.2. Programming Connector
The programming connector of the EMP 500 v7 /CLB is located at the end
of the coin selector (please see figure 1 and 2). The connector is a 5-pin
AMP connector type HE14. The connector has the following pin out:
PIN
No.
Connection
1
GND
2
UB (8 ... 18 V DC)
3
CLK
4
TDO
5
RDI
The programming connector is also used for the serial interfaces as well
as to connect the display D 500.
The following wiring diagram shows the serial interface located on the pcb
of the EMP 500 v7 /CLB.
Fig. 3 Wiring diagram serial programming connector and machine
interface
2.3. Programming of Coins
There are a variety of ways in which the coin acceptance of the
EMP 500 v7 /CLB may be programmed.
The coin selector can “learn” new coin parameters, including individual
tolerance requirements, with the help of the Calibration Function.
Calibration is carried out either using the PC based wheasy 5 software or
R3
10K
RXD1
T24
BC848B
ST3
1
2
3
4
5
L2 BLM21A
T1
BC848B
R5
1K
C2470pF
D23
BAS81
R9 10K
R4 1KD6 BAS81
L1 BLM21A
R72
10K
TXD1
GND
VCC5
GND
VCC3
GND
VCC3
Ub
serial port
E MP 500 v7
RDI
TDO
Ub
GND