User's Manual
15
LED Error Indicators Description
LED Definitions
• L4 (Yellow) = Program Running Indicator
•
L3 (Green) = Over-voltage Detection
(115±10
%
Vac, 60Hz and 230±10
%
Vac, 50Hz)
•
L2 (Red) = Overheat Detection
• L1 (Blue) = Continuous 250 times Operation Counting
Error Types
Note: If any of following errors occurs, the corresponding LED will turn on and
StealthPad will lock up. Turn the power switch off/on to reset the unit.
• [Red]
= Deactivating coils have overheated. Allow the unit to cool down
and reapply power.
• [Green] = Over-voltage detection of the power source (10% tolerance:
115±10%Vac@60Hz and 230±10%Vac@50Hz). Remove power until
the power source is brought within required limits.
• [Red] and [Yellow] = 250 times continuous deactivation count has
been reached. This typically occurs when the system false-alarms (e.g.
carelessly leaving a hard tag on the deactivation pad will cause false
alarms). In order to prevent system overheating from false alarms,
ensure there are no hard tags on the pad, thereby eliminating false
alarms, and then allow the system to cool down before reapplying
power.
• [All LEDs On] = Deactivator coils current has exceeded the limit.
Reapply power to the unit.
FAST PAD
CONTROL BOX
TM
L
A
N
R
E
M
O
T
E
C
O
N
T
R
O
L
L1L2L3L4
CONTROL BOX - FRONT VIEW
LED Error Indicators